STCW hours of rest checker

Enter seven consecutive days of rest to check at least 10 hours in every fully contained 24-hour window, 77 hours in seven days, splits in 24-hour windows starting at rest-period boundaries and gaps between rest periods.

Seven-day rest periods

Synthetic data

Use 30-minute steps; end may be 24:00. Split a midnight crossing into two entries; adjacent entries merge automatically.

Period 1
Period 2
Period 3
Period 4
Period 5
Period 6
Period 7
Period 8
Period 9
Period 10
Period 11
Period 12
Period 13
Period 14

Check results

Overall check: Pass

Total seven-day rest: 77 h

  • Rolling 24-hour rest ≥ 10 h: Pass

    Minimum: 11 h

  • Seven-day rest ≥ 77 h: Pass

    77 h

  • At most two periods per 24-hour window, one ≥ 6 h: Pass

    All split-check windows pass

  • Gaps between rest periods ≤ 14 h: Pass

    All internal gaps pass

The two-period and six-hour rule checks every fully contained 24-hour window starting at the start or end of a rest period. Rest before day 1 is not visible, so windows near the start of day 1 may differ from the full record. The 70-hour weekly and other exceptions, emergencies and drills are not evaluated.

Daily rest summary

DayRest (h)PeriodsLongest (h)
11126
21126
31126
41126
51126
61126
71126

How to use it

  1. 1

    Enter seven consecutive days

    Enter all rest periods using days 1 to 7 and HH:MM with minutes 00 or 30; time not entered counts as non-rest.

  2. 2

    Split midnight crossings

    End may be 24:00. Split a midnight crossing at 24:00 and 00:00 on the next day; adjacent entries merge automatically.

  3. 3

    Review the four checks

    Check a fully contained 24-hour window every half hour for at least 10 hours of rest, and at least 77 hours in seven days. Split checks use every fully contained 24-hour window starting at the start or end of a merged rest period: at most two pieces, with one lasting at least six hours if any rest occurs. Rest cut by the window end counts only its in-window length; internal gaps must not exceed 14 hours.

  4. 4

    Review and copy the details

    Review the minimum rest, first window failing the rest total, split failures with start day and time, period count and longest piece, and long gaps. Compare the daily summary with actual records and copy the result. Up to 10 failing split windows are listed.

Scope

  • The 70-hour weekly exception and other exceptions under STCW A-VIII/1 paragraph 9 and MLC A2.3.13 are not evaluated; emergencies and drills are not modelled.
  • The two-period and six-hour rule checks every fully contained 24-hour window starting at the start or end of a merged rest period. Only in-window rest pieces count, with pieces cut by the window end measured by their in-window length. Daily summaries are for display and do not decide the split result.
  • Rest before day 1 is not visible, so windows near the start of day 1 may differ from the full record; only fully contained windows and internal gaps between rest periods are checked.
  • Times use half-hour slots without time-zone conversion; results do not replace flag-state requirements, actual rest records or shipboard scheduling procedures.

Worked example

Synthetic dataSeven consecutive days, resting 00:00–06:00 and 12:00–17:00 each day
Daily rest
11 hours in two periods, longest 6 hours
Minimum rolling 24-hour rest
11 hours
Longest internal gap
7 hours
Four checks
All pass
Total seven-day rest
77 hours

All inputs are synthetic data; exactly 10 hours each day totals only 70 hours and fails the 77-hour check.

Questions

Does 10 hours of rest each day pass every check?

No. Seven days total only 70 hours, below this tool's 77-hour requirement; the 70-hour weekly exception is not evaluated.

How do I enter rest crossing midnight?

End the first entry at 24:00 and start the next day's entry at 00:00. Adjacent entries merge into continuous rest. Split windows start at the start or end of merged rest, never in its middle; rest cut by the window end counts only its in-window length.

Why show only the first window failing the rest total?

All 289 fully contained windows contribute to the minimum rest calculation; the first failing rest-total start locates the issue without listing many adjacent failures. Split checks use separate windows starting at rest-period boundaries and list up to 10 failures; the list limit does not change the pass result.

Does a pass establish full convention compliance?

No. The tool only checks fully contained windows within seven days, cannot see rest before day 1, and excludes exceptions, emergencies and drills; check actual records and applicable procedures.

Sources