Cargo · Petroleum mixtures
Crude oil tankers: H2S, static and inert gas
Crude oil may release hydrogen sulfide and benzene vapours; plan gas testing and exposure controls from cargo information. In inerted operations, control tank oxygen and positive pressure together; apply initial static-loading limits according to cargo and flammable-atmosphere conditions rather than to every crude oil.
Properties and data scope
| Property | Value or scope | Unit | Tag and source |
|---|---|---|---|
| Whole-cargo properties | Check properties and composition against the actual crude grade and cargo information; no universal values or composition ranges are assigned | — | Disclosed[S4] |
| Toxicity assessment | Actual constituents such as hydrogen sulfide and benzene | — | Disclosed[S1] |
| Temperature effects | Actual cargo temperature affects vapour pressure and gas release | — | Disclosed[S4] |
Cargo information and inert gas conditions
Check crude oil carriage under oil-tanker risk-management requirements; do not apply a single-chemical IBC Chapter 17 or IGC Chapter 19 entry. Determine inert gas system applicability from construction date, cargo and SOLAS requirements.[S2]
Oxygen limits are no more than 5% at the inert gas main outlet and 8% in cargo tanks, both by volume, with positive tank pressure maintained. The limits apply at different locations.[S2]
Initial loading and work after discharge
ISGOTT recommends an initial 1 m/s limit for static-accumulating oils when a flammable atmosphere may form, until the inlet and bottom structures are submerged by twice the inlet pipe diameter. Assess whether the actual cargo is a static accumulator; do not use this as a full-loading rate.[S3]
Tanks after discharge may retain hydrocarbon and toxic vapours. Before entering for cleaning or inspection, use the permit procedure and test oxygen, flammable gas and target toxic gases. Absence of odour does not replace testing.[S1]
Hydrogen sulfide and benzene detection
High hydrogen sulfide concentrations can disable smell; benzene odour is also an unreliable warning. Hydrogen sulfide detection does not replace benzene measurement. Following PID screening, quantify benzene with a suitable specific method.[S1]
Heating or agitation can release more dissolved hydrogen sulfide from oil into the vapour phase. Include work locations and sampling conditions in the gas-testing plan.[S1]
The US NIOSH H2S REL is a 10 ppm ceiling for 10 minutes. US OSHA general-industry 29 CFR 1910.1000 Table Z-2 lists a 20 ppm ceiling; a 50 ppm peak is allowed once for no more than 10 minutes only if no other measurable exposure occurs. These distinct occupational limits are not interchangeable TWA/STEL values or entry-atmosphere criteria; check applicability for the flag and work location.[S5][S6]
Questions
Does all crude oil share one flash point and density?
Check properties and composition using information for the actual crude grade and cargo; do not plan carriage from universal ranges.
Are 8% tank oxygen and 5% outlet oxygen the same limit?
No. They apply to cargo tanks and the inert gas main outlet respectively; inerted tanks also require positive pressure.
Must every crude oil start loading at 1 m/s?
Do not apply it directly. The recommendation applies to static-accumulating cargoes with possible flammable atmospheres and specifies an inlet-submergence condition.
Can crew enter because hydrogen sulfide cannot be smelled?
No. Smell can fail; gas testing and an entry permit under the applicable procedure are required.