Guide · Noxious liquid residues
MARPOL Annex II categories X, Y, Z and OS
Updated 2026-10-08 · About 7 min read
In one sentence
Annex II groups substances as X, Y, Z or OS by marine discharge hazard; X residues require prewash and shore reception, Y and Z retain operational controls, and mixtures containing only OS are outside Annex II discharge requirements.
Category definitions
| Category | Hazard and control | Tag and source |
|---|---|---|
| X | Major hazard to marine resources or health; direct residue discharge is prohibited. After regulation 13 prewash and shore reception, subsequent water is assessed separately. | Disclosed[S1][S2] |
| Y | Hazard to marine resources, health or other legitimate uses; discharge quality and quantity are restricted. | Disclosed[S1] |
| Z | Minor hazard, with less stringent restrictions but continued discharge controls. | Disclosed[S1] |
| OS | Evaluated outside X, Y and Z; relevant residue mixtures containing only these substances are not subject to Annex II discharge requirements. | Disclosed[S1] |
Strip first, then assess prewash
- 1
Strip under the Manual
Before prewash or discharge, empty the tank and piping to the maximum extent under the ship’s P&A Manual.[S2]
- 2
Send X prewash ashore
Complete the prescribed prewash before leaving the unloading port and send residues to reception facilities; subsequent water remains subject to applicable criteria.[S2]
- 3
Check Y prewash requirements for each cargo
Check Y prewash and residue-disposal requirements against the actual cargo, unloading conditions and the ship’s approved P&A Manual. Follow the latest flag and port authority requirements; the category alone does not establish a prewash obligation or exemption.[S2]
Criteria after discharge is permitted
| Check | Ordinary requirement | Tag and source |
|---|---|---|
| Speed | Proceeding en route at at least 7 knots if self-propelled, or 4 knots otherwise. | Disclosed[S2] |
| Distance and depth | At least 12 nautical miles from nearest land and water depth of at least 25 metres. | Disclosed[S2] |
| Outlet | Discharge below the waterline within the outlet’s maximum design rate; pre-1 January 2007 ships have an exception to the underwater-outlet requirement for Z substances. | Disclosed[S2] |
| Antarctic area | No discharge of noxious liquid substances or their mixtures south of latitude 60°S. | Disclosed[B1] |
A category is not a complete operating plan
- Determine procedures from the current product listing and the ship’s P&A Manual; a Y or Z label alone does not authorize discharge.[B1][S2]
- Keep Cargo Record Book entries for unloading, prewash and residue disposal, and coordinate reception facilities with the prewash plan.[B1]
- A following chemical cargo’s category does not automatically change the rules governing oily washwater from the previous cargo.[B2]
Questions
Is all water prohibited after carrying X cargo?
No. Prescribed prewash residues go ashore; water subsequently introduced is assessed under the relevant regulation 13 conditions.
Can every Y cargo avoid prewash?
No. Check prewash and exemption conditions against the actual cargo, unloading conditions and approved P&A Manual, following the latest flag and port authority requirements.
Do speed, distance and depth alone authorize discharge?
No. Category, stripping, prewash and the ship’s Manual must first permit the operation; then check those discharge criteria.